Open Architecture Radar Interface Standard Avatar
  1. OMG Specification

Open Architecture Radar Interface Standard — All Issues

  • Acronym: OARIS
  • Issues Count: 56
  • Description: All Issues
Closed All
All Issues

Issues Summary

Key Issue Reported Fixed Disposition Status
OARIS3-48 Inconsistent state condition for Health Service OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-44 service_health_type struct within Subsystem_Control IDL not in keeping with specification documentation. OARIS 2.0b2 OARIS 3.0b2 Closed; No Change closed
OARIS3-47 Update copyright holders OARIS 2.0 OARIS 3.0b2 Closed; No Change closed
OARIS3-53 IDL files are labelled as v1.1 not v2.0 OARIS 2.0 OARIS 3.0b2 Closed; No Change closed
OARIS3-60 Description of Control_Battle_Override protocol is inconsistent OARIS 2.0 OARIS 3.0b2 Deferred closed
OARIS3-113 instances of String in some IDL files OARIS 3.0a1 OARIS 3.0b2 Resolved closed
OARIS3-61 Two track_priority_type typedef classes defined OARIS 2.0b1 OARIS 3.0b2 Resolved closed
OARIS3-56 Manage Physical Configuration doesn't use common request response protocol OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-55 The state of a simulation session is not apparent on the interface OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-54 Representation of Ambiguity in Passive Bearings OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-50 PSM mapping for sensor_track_based_on_id_type has unexpected type OARIS 2.0b2 OARIS 3.0b2 Closed; No Change closed
OARIS3-57 Missing Reference OARIS 2.0 OARIS 3.0b2 Closed; No Change closed
OARIS3-51 request_id for report_service_health on subsystem intiative OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-49 Heartbeat required as the basis for on_requested_deadline_missed for DDS PSM OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-52 Mandatory velocity for sensor tracks doesn't work for bearings OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-59 Description of Manage_Tracking_Zones protocol is inconsistent OARIS 2.0 OARIS 3.0b2 Deferred closed
OARIS3-58 Description of Manage_Transmission_Sectors protocol is inconsistent OARIS 2.0 OARIS 3.0b2 Deferred closed
OARIS3-35 Transition from Lost to Normal should not rate-aid OARIS 2.0b2 OARIS 3.0b2 Closed; No Change closed
OARIS3-46 delete_sensor_track used as an interface and a method OARIS 2.0 OARIS 3.0b2 Resolved closed
OARIS3-38 Perform Offline test is in the wrong compliance level OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-33 Acquire and Release Mastership missing in PSM OARIS 2.0b2 OARIS 3.0b2 Closed; No Change closed
OARIS3-40 Add sensor performance operation for bias estimation OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-39 Duplicate Test Target activities for an interface OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-42 track_info_type blob contains info in the actual fields OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-45 technical_state_type incorrectly described as class when it is an enumeration OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-41 No operation to send system track to sensor unsolicited OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-37 IFF Sensor Parameter and Assessment issues OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-36 Overview activity diagrams are not legal UML OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-34 Some of the Normative References are not used normatively in the Spec OARIS 2.0b2 OARIS 3.0b2 Closed; No Change closed
OARIS3-43 Initial Emission Control State Undefined in Control_Emissions protocol OARIS 2.0 OARIS 3.0b2 Deferred closed
OARIS3-31 sensor_orientation_type is missing a rotation angle OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-22 No way to cancel a cued search OARIS 2.0 OARIS 3.0b2 Resolved closed
OARIS3-30 sensor_orientation_type assumes a single sensor OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-23 Range rate type only positive OARIS 2.0 OARIS 3.0b2 Resolved closed
OARIS3-20 Getting a 404 error when trying to download the OARIS 1.1 RTF -- Updated XMI file OARIS 1.1 OARIS 3.0b2 Closed; Out Of Scope closed
OARIS3-26 range_rate_type does not allow negative values OARIS 2.0b2 OARIS 3.0b2 Duplicate or Merged closed
OARIS3-28 multiple misspellings of "equipment" as "equipement" OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-27 system_track_type does not contain identity or classification OARIS 2.0b2 OARIS 3.0b2 Deferred closed
OARIS3-32 Remove ea_guid MethodTags OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-25 Incorrect units and range in description of NORTH_DOWN OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-18 contradiction on who (subsystem or CMS) should initiate the identification process and set the request id. OARIS 2.0b1 OARIS 3.0b2 Deferred closed
OARIS3-24 register_interest_type is missing service information OARIS 2.0 OARIS 3.0b2 Deferred closed
OARIS3-29 multiple misspellings of "spotting" as "splotting" OARIS 2.0b2 OARIS 3.0b2 Resolved closed
OARIS3-6 Document in legacy XMI 1.1 version OARIS 3.0b1 OARIS 3.0b2 Closed; No Change closed
OARIS3-15 acquire/release mastership - system requesting mastership is ambiguous OARIS 2.0 OARIS 3.0b2 Duplicate or Merged closed
OARIS3-16 Typo in ONLINE state description in the model OARIS 2.0 OARIS 3.0b2 Resolved closed
OARIS3-21 Changebar document seems to be for v2 to 3.0 beta 1 OARIS 2.0 OARIS 3.0b2 Closed; Out Of Scope closed
OARIS3-17 C2INav Model refers to an old OARIS Common Types package C2INAV 1.0 OARIS 3.0b2 Closed; No Change closed
OARIS3-3 Replace optional strings with typedefs OARIS 3.0a1 OARIS 3.0b2 Resolved closed
OARIS3-19 acquire and release mastership have no request_id to acknowledge OARIS 2.0 OARIS 3.0b2 Resolved closed
OARIS3-7 Remove mandated approach to subsystem integration in 8.2 OARIS 2.0 OARIS 3.0b2 Resolved closed
OARIS3-4 plot_association_type relationship to sensor_track_type incorrect OARIS 3.0a1 OARIS 3.0b2 Resolved closed
OARIS3-2 plot_summary_type is not mapped to an operation in the PIM OARIS 3.0a1 OARIS 3.0b2 Resolved closed
OARIS3-5 Redundant use of substem_id in plot_association_type OARIS 3.0a1 OARIS 3.0b2 Resolved closed
OARIS3-62 Attributes in XMI alphabetically sorted OARIS 3.0b1 OARIS 3.0b2 Resolved closed
OARIS3-1 PSM Section missing OARIS 3.0a1 OARIS 3.0b2 Resolved closed

Issues Descriptions

Inconsistent state condition for Health Service

  • Key: OARIS3-48
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    (originally reported by Richard Smith - BAE Systems)

    (Proivde_Health_State, page 194, para above table 7.185) contains the following description:

    “Reason for health state
    Each reported health state other than AVAILABLE is accompanied by the reason(s) for that health. In this way the CMS may for instance derive that although the technical state of the subsystem is STANDBY (and NOT AVAILABLE for that reason), there are also faults that would prevent the service to become AVAILABLE when the technical state would be switched to ONLINE.”

    This appears perfectly reasonable to me, although it is then followed immediately by:
    “Pre-condition: Subsystem technical state The subsystem is in technical state ONLINE or READY.”

    This appears to imply, to me, that the report service health is only applicable to the ONLINE or READY technical state, even though the para above suggests it would be of use in the STANDBY state!

  • Reported: OARIS 2.0b2 — Fri, 24 Feb 2023 10:41 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Include STANDBY as precondition to Provide_Health_State_CMS

    Include STANDBY as precondition to Provide_Health_State_CMS

  • Updated: Fri, 20 Dec 2024 23:14 GMT

service_health_type struct within Subsystem_Control IDL not in keeping with specification documentation.

  • Key: OARIS3-44
  • Status: closed  
  • Source: MCS-IA ( Jez Merchant-Locke)
  • Summary:

    Within Subsystem_Control.idl the struct service_health_type (line 327) has the member health_state (line 330) declared with type health_state_reason_type. The specification states it should be health_state_type. Believe this is an error?

  • Reported: OARIS 2.0b2 — Wed, 21 Jun 2023 08:20 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    service_health_type struct is correct in 3.0 beta

    service_health_type struct is correct in 3.0 beta and the health_state attribute has been changed to type health_state_type already.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Update copyright holders

  • Key: OARIS3-47
  • Status: closed  
  • Source: Real-Time Innovations ( Dr. Gerardo Pardo-Castellote, Ph.D.)
  • Summary:

    The copyright holders shown at the beginning of the document should include not only the original submitters but also the members of all the subsequent FTFs/RTFs. It seems this list has not been maintained as the following companies are missing:

    General Dynamics, Northrop Grumman, SimVentions, Microfocus, Real-Time Innovations,

  • Reported: OARIS 2.0 — Fri, 19 May 2023 05:17 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Copyright holders already updated for 3.0 beta

    Copyright holders already updated for 3.0 beta

  • Updated: Fri, 20 Dec 2024 23:14 GMT

IDL files are labelled as v1.1 not v2.0

  • Key: OARIS3-53
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The IDL files have the wrong interface version in them at the top of the file.

  • Reported: OARIS 2.0 — Mon, 9 Jan 2023 11:56 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Version has been removed from IDL files in later submissions

    Version has been removed from IDL files in later submissions

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Description of Control_Battle_Override protocol is inconsistent

  • Key: OARIS3-60
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The description of the interface states that
    "It is the CMS's responsibility to initiate the determination of initial state by making a request for information to the subsystem."
    However, there is no operation defined to request information from the subsystem.
    (Note: the protocol was probably simplified in working towards the v1.0 submission without revising the overall description of this particular interface).

  • Reported: OARIS 2.0 — Wed, 28 Sep 2022 11:58 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

instances of String in some IDL files

  • Key: OARIS3-113
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    there are several instances where the IDL generated from the XMI has String (capitalised) rather than in lower case which causes an error in some DDS IDL compilers. These should be generated as lower case in the following files:
    Manage_Network_Participation.idl
    Plot_Reporting.idl
    Track_Reporting.idl
    Label_Tracks.idl

  • Reported: OARIS 3.0a1 — Mon, 9 Sep 2024 20:48 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    In affected IDL files replace String with string

    In the 4 affected IDL files replace the capitalised String with all lower case string and resubmit the zipped IDL files

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Two track_priority_type typedef classes defined

  • Key: OARIS3-61
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    There are track_priority_type typedefs defined in both the Track_Reporting and Tracking_Control Domain Model packages.

  • Reported: OARIS 2.0b1 — Mon, 25 Jul 2022 16:51 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    OARIS 3.0 beta has already addressed this

    OARIS 3.0 beta has already addressed this by creating a common definition which is then used in specific unions elsewhere

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Manage Physical Configuration doesn't use common request response protocol

  • Key: OARIS3-56
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    Interface Manage_Physical_Configuration_CMS contains method receive_physical_configuration_success, which is used where receive_acknowledgement from common_use_case_interface would be expected

  • Reported: OARIS 2.0b2 — Fri, 16 Dec 2022 08:44 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

The state of a simulation session is not apparent on the interface

  • Key: OARIS3-55
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    Method report_sim_mode_status does not contain the status of the session e.g. whether it is running, not started, frozen etc. The specification should also describe the overall state machine described by the interface.

  • Reported: OARIS 2.0b2 — Fri, 16 Dec 2022 14:10 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Representation of Ambiguity in Passive Bearings

  • Key: OARIS3-54
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    Some passive sensors are unable to resolve a bearing around the line of symmetry through the sensor. The polar model for positions in the specifications does not allow this ambiguity to be clearly represented.

  • Reported: OARIS 2.0b2 — Fri, 16 Dec 2022 16:04 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

PSM mapping for sensor_track_based_on_id_type has unexpected type

  • Key: OARIS3-50
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    typedef sequence<org::omg::c4i::Domain_Model::Common_Types::subsystem_id_type, 256> sensor_track_based_on_id_type;

    Has subsystem_id_type rather than plot_id_type as its value type.

  • Reported: OARIS 2.0b2 — Thu, 23 Feb 2023 11:27 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Fixed in OARIS 3.0

    Relationship has been changed through a plot association type and so this issue is no longer valid.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Missing Reference

  • Key: OARIS3-57
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Paul Marsh)
  • Summary:

    METOC RFP (c4i/08-12-02) is referenced in dtc/22-06-03 but does not yet exist on the OMG site in any form.

  • Reported: OARIS 2.0 — Mon, 10 Oct 2022 15:11 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Reference was removed from 3.0 beta

    The missing reference was already removed from 3.0 beta submission

  • Updated: Fri, 20 Dec 2024 23:14 GMT

request_id for report_service_health on subsystem intiative

  • Key: OARIS3-51
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    For Service Health Reporting and Subsystem Health Reporting the specification describes two scenarios one on subsystem initiative and another on request.
    In both cases the subsystem calls a method on the CMS interface with a request_id. In the 'on subsystem initiative' case it is unclear what value the subsystem should use for the request_id. Any value chosen could potentially be misinterpreted as a value for an actual CMS request.

  • Reported: OARIS 2.0b2 — Wed, 8 Feb 2023 15:31 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Add functions to provide health reporting on subsystem initiative

    Add functions to provide health reporting on subsystem initiative - i.e. the same as those requested by the CMS but without the request ID.

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Heartbeat required as the basis for on_requested_deadline_missed for DDS PSM

  • Key: OARIS3-49
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The Exchange Heartbeat use case supports assurance cases relating to runtime software integrity, in particular that critical functionality continues to be available and has not failed silently.
    For the DDS PSM this is currently mapped to the built-in DDS API, but the on_requested_deadline_missed requires a suitable topic definition (which could/should be provided by the Exchange Heartbeat use case).

  • Reported: OARIS 2.0b2 — Thu, 23 Feb 2023 14:42 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Mandatory velocity for sensor tracks doesn't work for bearings

  • Key: OARIS3-52
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    Attribute velocity in class sensor_track_type is mandatory but will not be defined / known for bearings tracks

  • Reported: OARIS 2.0b2 — Wed, 11 Jan 2023 18:04 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Make azimuth optional on the polar velocity type

    Make azimuth_rate optional on the polar velocity type to allow for sensor which report bearing only tracks

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Description of Manage_Tracking_Zones protocol is inconsistent

  • Key: OARIS3-59
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The description of the interface states that
    "It is the CMS's responsibility to initiate the determination of initial state by making a request for information to the subsystem."
    However, there is no operation defined to request information from the subsystem.
    (Note: the protocol was probably simplified in working towards the v1.0 submission without revising the overall description of this particular interface).

  • Reported: OARIS 2.0 — Wed, 28 Sep 2022 14:52 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Description of Manage_Transmission_Sectors protocol is inconsistent

  • Key: OARIS3-58
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The description of the interface states that
    "It is the CMS's responsibility to initiate the determination of initial state by making a request for information to the subsystem."
    However, there is no operation defined to request information from the subsystem.
    (Note: the protocol was probably simplified in working towards the v1.0 submission without revising the overall description of this particular interface).

  • Reported: OARIS 2.0 — Wed, 28 Sep 2022 10:59 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Transition from Lost to Normal should not rate-aid

  • Key: OARIS3-35
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    ...

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:53 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Issue not present in 3.0 beta

    The issue reported in 2.0 does not appear to be present in 3.0 beta

  • Updated: Fri, 20 Dec 2024 23:14 GMT

delete_sensor_track used as an interface and a method

  • Key: OARIS3-46
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    delete_sensor_track is used as an interface in the Tracking_Control service and as a method on the Provide_Sensor_Tracks interface. This is potentially confusing and in principle could cause name clashes.

  • Reported: OARIS 2.0 — Tue, 20 Jun 2023 12:29 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Rename delete_sensor_track method to end_sensor_track

    Rename the delete_sensor_track method in the Provide_Sensor_Tracks_CMS interface to end_sensor_track

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Perform Offline test is in the wrong compliance level

  • Key: OARIS3-38
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    Perform Offline test should be compliance level 3A not 3B

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:50 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Move Perform Offline Test to compliance level 3A

    Move Perform Offline Test to compliance level 3A. Text and associated diagrams

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Acquire and Release Mastership missing in PSM

  • Key: OARIS3-33
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The DDS topic types for PIM operations acquire_mastership and release_mastership are both missing from the IDL. Additionally request_id is a missing parameter from these operations, as otherwise the receive_acknowledgement operations in the sequence diagrams have an undefined source of request_id.

  • Reported: OARIS 2.0b2 — Fri, 27 Jan 2023 12:34 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Acquire mastership already present in 3.0 IDL

    This problem was already fixed in 3.0 beta

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Add sensor performance operation for bias estimation

  • Key: OARIS3-40
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    An important aspect of sensor performance estimation is to understand bias particularly for atmospheric effects.

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:48 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Duplicate Test Target activities for an interface

  • Key: OARIS3-39
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    There are two activities "Define Test Target Scenario" & "Control Test Target Facility" for one interface

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:49 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

track_info_type blob contains info in the actual fields

  • Key: OARIS3-42
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    .

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:35 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Remove suggested items from additional_information description

    Remove suggested items from additional_information description that are already present as attributes on the type:
    priority
    identification

  • Updated: Fri, 20 Dec 2024 23:14 GMT

technical_state_type incorrectly described as class when it is an enumeration

  • Key: OARIS3-45
  • Status: closed  
  • Source: Naval Combat Systems Integration Support Service ( Matthew Burleigh)
  • Summary:

    On page 95 the description of technical_state_type calls it a class while the diagrams stereotype it as an IDLEnum.

  • Reported: OARIS 2.0b2 — Wed, 3 May 2023 13:25 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Change description of technical_state_type

    Change description of technical_state_type to IDLEnum

  • Updated: Fri, 20 Dec 2024 23:14 GMT

No operation to send system track to sensor unsolicited

  • Key: OARIS3-41
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    This is a useful mode of operation ...

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:46 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

IFF Sensor Parameter and Assessment issues

  • Key: OARIS3-37
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    to be elaborated ...

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:51 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Overview activity diagrams are not legal UML

  • Key: OARIS3-36
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    ...

  • Reported: OARIS 2.0b2 — Sat, 23 Sep 2023 12:52 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Change types from activity to action

    types used in the activity diagrams are all activity rather than action which would be preferred in current UML.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Some of the Normative References are not used normatively in the Spec

  • Key: OARIS3-34
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    For example CORBA, ALMAS & AMSM

  • Reported: OARIS 2.0b2 — Thu, 28 Sep 2023 18:47 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Normative References were already updated at 3.0 beta

    Normative References were already updated at 3.0 beta with CORBA, ALMAS and AMSM not present

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Initial Emission Control State Undefined in Control_Emissions protocol

  • Key: OARIS3-43
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The interaction diagrams for the Control_Emissions service do not provide a mechanism for determining the initial state of the emission control setting.
    Possibilities are that the CMS is expected to explicitly set this for all sensors as part of startup of each sensor (e.g. whilst they are in the READY state) or that each sensor has its own default (or persistent) state that it assumes on each startup.
    Further information: The description of the ONLINE technical state, requires Control Emissions to occur once the subsystem is in this state and implies that the emission control setting is off when the subsystem enters the ONLINE state.
    More information: The description of the Control_Emissions_CMS interface states: "It is the CMS's responsibility to initiate the determination of initial state by making a request for information to the subsystem." However there is no method on the subsystem interface to provide this information.
    The description of Control_Emissions_CMS interface should be updated accordingly.

  • Reported: OARIS 2.0 — Wed, 28 Sep 2022 09:19 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

sensor_orientation_type is missing a rotation angle

  • Key: OARIS3-31
  • Status: closed  
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    The sensor orientation message reports the orientation of the sensor with two angles: azimuth and elevation. But to completely describe orientation, three angles are required. The missing angle is a rotation about the normal from the array. It can becalled a clocking angle. Using azimuth and elevation correspond to Cardan angles, which describe orientation as heading, elevation, and bank. The missing angle in this system is the bank angle. See https://en.wikipedia.org/wiki/Euler_angles

  • Reported: OARIS 2.0b2 — Wed, 27 Sep 2023 13:46 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Add bank angle to sensor_orientation_type

    Create a new type for bank angle and add to the sensor_orientation_type class.

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

No way to cancel a cued search

  • Key: OARIS3-22
  • Status: closed  
  • Source: Swordfish Computing ( Cameron Bunge)
  • Summary:

    Searches can potentially take a long time, there is no message/interaction to stop one once its in progress. Suggest adding a stop_cued_search as with stop_surveillance.

  • Reported: OARIS 2.0 — Tue, 19 Dec 2023 04:19 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Add stop_cued_search operation to Perform_Cued_Search_Sub interface

    Add stop_cued_search operation to Perform_Cued_Search_Sub interface. Update the table describing the operation and the sequence diagram to show usage.

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

sensor_orientation_type assumes a single sensor

  • Key: OARIS3-30
  • Status: closed  
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    The sensor orientation message reports the orientation of the sensor relative to a specified coordinate system. However, if a radar has multiple sensors there is no way to distinguish between them. I suggest adding an optional sensor_id field (type short) to distinguish between multiple sensors.

  • Reported: OARIS 2.0b2 — Wed, 27 Sep 2023 14:01 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Add optional sensor_id to sensor_orientation_type

    Add optional sensor_id to sensor_orientation_type of type short

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Range rate type only positive

  • Key: OARIS3-23
  • Status: closed  
  • Source: Swordfish Computing ( Cameron Bunge)
  • Summary:

    Range rate type limited to 0-1e5, this should also accept negative values for closing rates. Also an issue in version 3 beta.

  • Reported: OARIS 2.0 — Tue, 19 Dec 2023 04:11 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Modify range to allow negative

    Change the range on range_rate_type to be -1 e5 .. 1 e5

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Getting a 404 error when trying to download the OARIS 1.1 RTF -- Updated XMI file


range_rate_type does not allow negative values

  • Key: OARIS3-26
  • Status: closed  
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    range_rate_type is used to quantify the rate of change of the range. The range of allowed values is 0.0 to 1e5, but this is too restrictive. Range rate is negative when an object is getting closer to the origin, i.e. the range is decreasing so range rate is negative. The lower bound of range rate should be -1e5, the negative of the maximum value.

  • Reported: OARIS 2.0b2 — Mon, 30 Oct 2023 18:40 GMT
  • Disposition: Duplicate or Merged — OARIS 3.0b2
  • Disposition Summary:

    Fixed by duplicate issue OARIS3-23

    Fixed by duplicate issue OARIS3-23

  • Updated: Fri, 20 Dec 2024 23:14 GMT

multiple misspellings of "equipment" as "equipement"

  • Key: OARIS3-28
  • Status: closed  
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    The specification and Sensor_Assessment.idl have multiple misspellings of "equipment" as "equipement". All of the misspellings are in types and structs related to sensor_plot_equipement_assessment.

  • Reported: OARIS 2.0b2 — Wed, 27 Sep 2023 18:22 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Update diagram 7.158 to correct spelling

    Update diagram 7.158 to correct spelling

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

system_track_type does not contain identity or classification

  • Key: OARIS3-27
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    system_track_type does not contain identity or classification

  • Reported: OARIS 2.0b2 — Mon, 23 Oct 2023 16:19 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Remove ea_guid MethodTags

  • Key: OARIS3-32
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    These tags are meaningless in the specification.

  • Reported: OARIS 2.0b2 — Fri, 6 Oct 2023 16:43 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Remove ea_guid tags from the model

    Remove ea_guid tags from methods in the model

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Incorrect units and range in description of NORTH_DOWN

  • Key: OARIS3-25
  • Status: closed  
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    The description of the NORTH_DOWN in coordinate_orientation_type says:

    Valid for Polar Coordinate Kind
    Azimuth has origin (0.0) at North, clockwise positive, measured in the horizontal plane
    Elevation has origin (0.0) when pointing directly down, and 180.0 degrees when pointing directly up, measured in the vertical plane.

    This would be fine except the elevation_coordinate_type specifically says units are radians with values from -PI/2 to +PI/2.

    I suggest changing the maximum value of elevation in the description of NORTH_DOWN from 180.0 degrees to PI radians and change the maximum value of elevation_coordinate_type from +PI/2 to +PI.

  • Reported: OARIS 2.0b2 — Mon, 30 Oct 2023 19:25 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Change NORTH_DOWN descriptive text and elevation_coordinate_type max limit

    Change the maximum value of elevation in the description of NORTH_DOWN from 180.0 degrees to PI radians and change the maximum value of elevation_coordinate_type from +PI/2 to +PI.

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

contradiction on who (subsystem or CMS) should initiate the identification process and set the request id.

  • Key: OARIS3-18
  • Status: closed  
  • Source: BAE Systems ( Jia Liu)
  • Summary:

    The following is the description of request_id in oaris 2.0 spec:

    7.3.12.6 request_id_type
    Type: IDLTypeDef unsigned long long
    Package: Requests
    The purpose of the request_id is to uniquely relate responses of the subsystem (server) to requests of the CMS (client). The request_id is set by the client. It is the responsibility of the client to specify a system-wide unique request_id (e.g. based on a combination of client id and a sequence number / time of request). Here it indicates that CMS as client should specify request_id. But in section 7.7.5.3 Provide_Subsystem_Identification, it documents that it should be the subsystem to initiate the communication to CMS, which implies subsystem will need to specify request_id required in receive_sub_identification_data_type before sending it to CMS.

  • Reported: OARIS 2.0b1 — Tue, 13 Sep 2022 16:29 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

register_interest_type is missing service information

  • Key: OARIS3-24
  • Status: closed   Implementation work Blocked
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    The OARIS 2.0 specification says registration includes information on:

    • The service for which the actor wants to register / deregister his interest
    • The information within the service for which the actor wants to register / deregister his interest
    • The intended (direct or indirect) recipient(s) of the information provided by the subsystem
    • Any parameters of the provision needed such as Quality of Service parameters

    But according to the IDL, register_interest_type contains a sequence of interest_type, which contains only the registration type (REGISTER or DEREGISTER), the recipent, and quality of service. The message has no way to specify a service or information within a service; the first two bullet points in the requirements above.

  • Reported: OARIS 2.0 — Tue, 28 Nov 2023 22:00 GMT
  • Disposition: Deferred — OARIS 3.0b2
  • Disposition Summary:

    Defer to 3.1 RTF

    This issue was raised against OARIS 2.0 and transferred into the OARIS 3.0 FTF very recently and after the comment deadline. In order to not delay the OARIS 3.0 FTF it is proposed to defer this issue for resolution in OARIS 3.1 which will be chartered at the successful conclusion of this FTF.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

multiple misspellings of "spotting" as "splotting"


Document in legacy XMI 1.1 version

  • Key: OARIS3-6
  • Status: closed   Implementation work Blocked
  • Source: qinetiq ( ben xavier)
  • Summary:

    Sparx Enterprise Architect A (build v 16.1..1626) reports that the OARIS v3 beta (also v2 beta) XMI document is in XMI Version 1.1 - which is no longer supported by recent versions of EA.

    Suggest specifying XMI 2.1 schema in source tooling and reissuing for compatibility.

  • Reported: OARIS 3.0b1 — Thu, 11 Apr 2024 09:58 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Export XMI in XMI 2.5.1

    When publishing from EA, ensure that UML 2.5 (XMI 2.5.1) is chosen as the export format.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

acquire/release mastership - system requesting mastership is ambiguous

  • Key: OARIS3-15
  • Status: closed  
  • Source: RTX ( Dr. David Bainbridge)
  • Summary:

    The acquire and release mastership messages have only a "count" field. There is no way for the radar to determine which system is requesting or releasing mastership. The radar needs to know the identity of the master when reporting mastership. Suggest adding a subsystem ID to acquire and release mastership messages.

  • Reported: OARIS 2.0 — Mon, 15 Apr 2024 15:49 GMT
  • Disposition: Duplicate or Merged — OARIS 3.0b2
  • Disposition Summary:

    Issue is duplicated by OARIS3-19

    Issue is duplicated (in part) by OARIS3-19. The resolution for OARIS 3-19 will resolve this issue.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Typo in ONLINE state description in the model

  • Key: OARIS3-16
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The notes field for the ONLINE state in the Technical State state machine has a typo - viathe. The notes field has other subtle differences in comparison to the corresponding enumeration attribute.

  • Reported: OARIS 2.0 — Wed, 28 Sep 2022 10:49 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    fix the typo in the notes for the ONLINE state

    Fix the typo in the model. This does not affect the generated specification as the diagram and text is not present in the specification document

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Changebar document seems to be for v2 to 3.0 beta 1

  • Key: OARIS3-21
  • Status: closed  
  • Source: MCS-IA ( Jez Merchant-Locke)
  • Summary:

    Can this please be checked. Looking at OARIS v1.1 changebar this documents the changes from v1.0 to v1.1. The changebar document published on v2.0 should therefore be the changes from v1.1 to v2.0. The document published shows the changes from version v2.0 to v3 beta 1

  • Reported: OARIS 2.0 — Thu, 4 Jan 2024 13:31 GMT
  • Disposition: Closed; Out Of Scope — OARIS 3.0b2
  • Disposition Summary:

    Not an OARIS 3.0 FTF Issue

    Not an OARIS 3.0 FTF Issue

  • Updated: Fri, 20 Dec 2024 23:14 GMT

C2INav Model refers to an old OARIS Common Types package

  • Key: OARIS3-17
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Simon Mettrick)
  • Summary:

    The C2INav Model refers to a package defined by OARIS 1.1.
    OARIS 2.0 is about to be published and there are 2.1 RTF & 3.0 FTF in progress.

  • Reported: C2INAV 1.0 — Wed, 21 Jun 2023 10:00 GMT
  • Disposition: Closed; No Change — OARIS 3.0b2
  • Disposition Summary:

    Does not apply to OARIS specification

    This is an issue affecting C2INav and does not affect OARIS. There is a separate issue raised on C2INav (https://issues.omg.org/browse/C2INAV13-1)

  • Updated: Fri, 20 Dec 2024 23:14 GMT

Replace optional strings with typedefs

  • Key: OARIS3-3
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    The syntax for an optional string (parameter_range: string [0..1]) can cause confusion to parsers of the XMI as to whether the syntax is for being optional or fixed length.
    Optional strings would be better defined as an optional TypeDef.

    This affects parameter_range and typical_value in the descriptor_type struct within Subsystem_Domain -> Subsystem_Control

  • Reported: OARIS 3.0a1 — Mon, 9 Oct 2023 09:23 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Create Typedefs for optional strings

    replace the parameters which are of type string [0..1] with typedefs in the descriptor_type class

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

acquire and release mastership have no request_id to acknowledge


Remove mandated approach to subsystem integration in 8.2

  • Key: OARIS3-7
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    Section 8.2 mandates how topics and partitions should be used to include different subsystems into an OARIS based system.

    However the approach mandated is not the only approach and other approaches may be used and be more suitable for a given use case. This section should be re-written to provide some guidance examples rather than mandates

  • Reported: OARIS 2.0 — Mon, 1 Jul 2024 12:23 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Reword section 8.2

    Reword section 8.2 to give guidance to a system integrator rather than mandate a particular approach.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

plot_association_type relationship to sensor_track_type incorrect

  • Key: OARIS3-4
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    The relationship between plot_association_type and sensor_track_type should be a composition such that the sensor track contains a collection of plot_association_type objects rather than a collection of references which can not be resolved as the plot_association_type does not have an id and is not published separately on another topic.

  • Reported: OARIS 3.0a1 — Wed, 10 Jan 2024 08:51 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    change plot_association relationship to composition

    change the sensor_track_type to be a compostion of plot_association_types

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

plot_summary_type is not mapped to an operation in the PIM

  • Key: OARIS3-2
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    The class plot_summary_type was expected to be a topic type, but it isn’t mapped to an operation in the PIM – so it isn’t. We need to add a suitable operation to the Provide_Plots or Provide_Sensor_Orientation interface.

  • Reported: OARIS 3.0a1 — Tue, 5 Sep 2023 11:05 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Add plot_summary_type to method on Provide_Plots_CMS

    Add a method write_sensor_plot_summary to the Provide_Plots_CMS interface taking a parameter of type plot_summary_type.

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Redundant use of substem_id in plot_association_type

  • Key: OARIS3-5
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    The plot_association_type contains both a plot_subsystem attribute and a plot_id attribute which contains a subsystem_id attribute.

    These both refer to the same piece of information and therefore one is redundant and should be removed.

  • Reported: OARIS 3.0a1 — Wed, 13 Mar 2024 08:39 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Remove plot_subsystem attribute from plot_association_type

    Remove the plot_subsystem attribute from the plot_association_type struct

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments:

Attributes in XMI alphabetically sorted

  • Key: OARIS3-62
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    The exported XMI from the EA model has been generated with the option selected to alphabetically sort the attributes in the model. This does not affect the word specification but does impact the XMI and IDL.

  • Reported: OARIS 3.0b1 — Thu, 11 Jul 2024 06:48 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Export XMI without alphabetical sorting enabed

    For the 3.0 FTF submission, ensure that the XMI (and hence the generated IDL) has not had alphabetical sorting of attributes applied on export.

  • Updated: Fri, 20 Dec 2024 23:14 GMT

PSM Section missing

  • Key: OARIS3-1
  • Status: closed  
  • Source: BAE SYSTEMS ( Mr. Ollie Newman)
  • Summary:

    The PSM section of the document was omitted from the submission and should be re-instated

  • Reported: OARIS 3.0a1 — Tue, 5 Sep 2023 11:04 GMT
  • Disposition: Resolved — OARIS 3.0b2
  • Disposition Summary:

    Re-insert PSM section

    Re-insert the PSM section as written for the 2.0 standard into the 3.0 standard

  • Updated: Fri, 20 Dec 2024 23:14 GMT
  • Attachments: