Unified POS Avatar
  1. OMG Specification

Unified POS — All Issues

  • Acronym: UPOS
  • Issues Count: 9
  • Description: All Issues
Open Closed All
All Issues

Issues Descriptions

Revised UPOS 1.16 (dtc-20-12-01.docx)spec. is proposed as UPOS 1.16.1

  • Key: UPOS1161-1
  • Status: closed  
  • Source: Microsoft ( Mr. Tadashi Furuhata)
  • Summary:

    We have found an item in UPOS 1.16 (dtc-20-12-01.docx) that needs to be modified as a specification.
    All of these items are extracted, issues and correction items are clearly shown, and the corrections and edits of the specification items are proposed as UPOS 1.16.1.
    Attached documents are as follows.
    1) UPOS RCSD 1.16 Issues Table
    Note :All of the to be corrected items in the UPOS 1.16 spec. is listed up.
    2) UPOS RCSD 1.16.1_withBar.docx
    Note: All of the issues to be corrected is listed and indicated line by line with the explanation.
    3) UPOS RCSD 1.16.1_clean.docx
    Note: Clean file of UPOS RCSD 1.16.1
    These documents have only RCSD related 11 device chapters.
    That is to say;
    Chapter 21 Lights
    Chapter 29 POS Power
    Chapter 39 Video Capture
    Chapter 40 Individual Recognition
    Chapter 41 Sound Recorder
    Chapter 42 Voice Recognition
    Chapter 43 Sound Player
    Chapter 44 Speech Synthesis
    Chapter 45 Gesture Control
    Chapter 46 Device Monitor
    Chapter 47 Graphic Display

  • Reported: UPOS 1.16b2 — Thu, 18 Nov 2021 14:04 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    All of UPOS1.16.1 issue resolved documents

    After discussion with Denis and OMG Retail DTF member, finally we reached to the all issues resolved version.
    As the final submission version documents are listed below.
    1. Original UPOS 1.16
    dtc-20-12-01.docx
    2. UPOS1.16 Issue and Resolved Item Listed Table
    UPOS RCSD 1.16 Issues Table_02032022.xlsx
    3. UPOS1.16.1 with Bar + Issue Item and revised item Table
    UPOS RCSD 1.16.1_02032022_withBar.docx
    4. UPOS1.16.1 clean Version (UPOS1.16.1 Final Version Candidate)
    UPOS RCSD 1.16.1_02032022_clean.docx

    Please take look at those, and after your review, I would like to go to the voting for your approval.

    Regards.

    Tad Furuhata

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

Video Capture ER_CONTINUEINPUT should be ER_RETRY, "input" should be "data"

  • Key: UPOS1161-6
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Video Capture ER_CONTINUEINPUT should be ER_RETRY, "input" should be "data"

    Examples:

    Error Event behavior was incorrect.

    ER_CONTINUEINPUT was incorrect and should be changed to
    ER_RETRY

    clearInput method description of "input" should be changed to "data".

    ErrorEvent description of "input" should be changed to "data".

    -------------

    Issue Group D

    Remarks in bar doc:

    P89
    P90
    P91

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 03:36 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Video Capture ER_CONTINUEINPUT to ER_RETRY, and "input" to "data"

    See attached spreadsheet for extent of modifications.

    Video Capture ER_CONTINUEINPUT should be ER_RETRY, "input" should be "data"

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

Missing remarks, status description improvement, capability read-write vs read-only and ErrorResponse improvements

  • Key: UPOS1161-4
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Missing remarks, repairing typos and descriptions. Retry behavior improperly documented for input vs output device behavior.

    Examples:

    Capability needs to be used under the read-only, however description was read-write. This should be corrected.

    In addition, regarding the Remarks section, description was not good enough to explain this property’s behavior.

    In the Remarks initialization description was missing.

    In the See also section, referenced properties were missing.

    In Attribute, regarding the ErrorResponse value, ER_RETRY should be eliminated, since this is the input device.
    Also, in the ER_CLEAR output device related description was corrected since there are typo of loci and there is not output data because of input device.

    In See Also section, Status, Error code, State model description were not needed.
    Then “Device Input Model” on page Intro-22” and “Error Handling” on page Intro-23 were added instead.

    -------------

    Issue Group B

    Remarks in bar doc:

    P84
    P85
    P89
    P90
    P90
    P90
    P91
    P93
    P96
    P97
    P102
    P106
    P107
    P108
    P113
    P128
    P129
    P138
    P143
    P146
    P164
    P174
    P174
    P178
    P196
    P205
    P218
    P232
    P240
    P241
    P241
    P246
    P247
    P252
    P252
    P254

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 03:16 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Added missing remarks, improved status descriptions, repaired capability read-write vs read-only and ErrorResponse improvements for UPOS1161-4

    See attached spreadsheet for extent of modifications.

    Example:

    39/ Video Capture

    CapAssociatedHardTotalsDevice Property

    Capability needs to be used under the read-only, however description was read-write. Therefore, it was changed from read-write to read-writeonly.
    In addition, regarding the Remarks section, description was not good enough to explain this property’s behavior.
    Therefore, “Holds the open name of the associated Hard Totals device, if the device is able to write to such devices which is the case, if CapStorage is either VCAP_CST_ALL or VCAP_CST_HARDTOTALS_ONLY.
    If CapStorage is VCAP_CST_HOST_ONLY this property value must be the empty string. “was corrected as follows.
    “Indicate that the device is able to store the recorded data into the Associated Hard Totals device and Hholds the its open name of the associated Hard Totals Device, if the device is able to write to such devices which is the case, if CapStorage is either VCAP_CST_ALL or VCAP_CST_HARDTOTALS_ONLY.
    If CapStorage is VCAP_CST_HOST_ONLY, the device is not able to store the data into the Associated Hard Totals device and this property value must be the empty string. This property is initialized by the open method.

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

Method and property "open claim enable" combinations and E_ILLEGAL error code definitions

  • Key: UPOS1161-3
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Repairing documentation to match expected implementation.

    Examples:

    This method can be used after open claim enable, however summary section missing the claim and it was added in the use after section.

    This property is able to read and write. In that case there should be the E_ILLEGAL error code. However, that description was missing. Therefore, E_ILLEGAL related description was added as listed below.
    Some possible values of the exception’s ErrorCode property are:
    Value Meaning
    E_ILLEGAL An invalid value was specified.

    --------------

    Issue Group A

    Remarks in bar doc:

    P38
    P52
    P67
    P68
    P74
    P85
    P92
    P93
    P99
    P100
    P101
    P102
    P103
    P104
    P105
    P106
    P107
    P116
    P126
    P133
    P139
    P140
    P141
    P149
    P168
    P175
    P181
    P199
    P221
    P235
    P236
    P247

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 03:01 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Property and method descriptions adjusted for UPOS1161-3

    See attached spreadsheet for proposed modifications.

    Example:

    39/ Video Capture

    VideoFrameRate Property

    This property needs to be used under the open, claim enable, however is the spec claim, enable were missing and newly added.
    Access after open, claim enable.
    In the See also section, CapVideoFrameRate Property was missing, therefore it was added.

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

StatusUpdateEvent values and description in Remarks need improvement

  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    StatusUpdateEvent values and description in Remarks need improvement

    Examples:

    39/ Video Capture

    TakePhoto

    In the Remarks, StatusUpdateEvent related description was not good enough. Therefore, those description was added.
    “The process of recorded data storing is performed asynchronously. StatusUpdateEvents are invoked for delivered to the application when the start and the end state were changed.”

    -------------

    Issue Group H

    Remarks in bar doc:

    P89
    P90
    P109
    P110
    P111
    P114

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 04:06 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Improved StatusUpdateEvent values and description in Remarks

    Method descriptions, remarks and specific instances of StatusUpdateEvent needed improvement.

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

Read-only properties mistakenly marked read-write, and missing Remarks

  • Key: UPOS1161-9
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Read-only properties mistakenly marked read-write, and missing Remarks

    Examples:

    43/ Sound Player

    CapAssociatedHardTotalsDevice Property

    This property can be used as read only, therefore, read-write was corrected as read-only.
    In the Remarks initialization description was missing.
    Therefore, this description was added.
    This property is initialized by the open method.

    -------------

    Issue Group G

    Remarks in bar doc:

    P168
    P173
    P188
    P243

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 04:01 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Fixed read-only property designations and added missing remarks for UPOS1161-9

    Some properties were mistakenly described as read-write when they should be read-only. Also clarified descriptions.

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

Cover page version and submission date

  • Key: UPOS1161-5
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Cover page version and submission date

    Examples:

    In the cover page there was an old description. This specification proposing the UPOS 1.16.1 and it editing the UPOS1.16. Also, documentation submission date is Sept. 2021.

    -------------

    Issue Group C

    Remarks in bar doc:

    P14

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 03:28 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Cover page and submission date adjusted for UPOS1161-5

    In the cover page there was an old description. This specification was intended to be UPOS 1.16.1 as an adjustment to UPOS1.16. Also, documentation submission date was Sept. 2021.

  • Updated: Wed, 13 Jul 2022 14:18 GMT

Method behavior descriptions missing several conditions

  • Key: UPOS1161-8
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Method behavior descriptions missing several conditions

    Examples:

    47/ Graphic Display...

    clearInput Method, clearInputProperties Method, clearOutput Method

    This method behavior description missing the several conditions. Therefore, those are newly added.

    void:

    {raises-exception, use after open, claim}

    -------------

    Issue Group F

    Remarks in bar doc:

    P116
    P132
    P133
    P149
    P168
    P181
    P182
    P199
    P221
    P235
    P236

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 03:48 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Added missing method conditions for UPOS1161-8

    See attached spreadsheet for extent of modifications.

    Example:

    42/ Voice Recognition
    ClearInput Method,
    ClearInputProperties Method

    Added: void:

    {raises-exception, use after open, claim}
  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments:

Method use descriptions accidentally comma delimited, not consistent with others

  • Key: UPOS1161-7
  • Status: closed  
  • Source: Lexmark ( Mr. Andy Mattice)
  • Summary:

    Method use descriptions accidentally comma delimited, not consistent with others

    Examples:

    POS Power restartPOS and shutdownPOS methods...

    Therefore, use after open,
    enable is changed to use after open-enable.

    -------------

    Issue Group E

    Remarks in bar doc:

    P77
    P78
    P90
    P91
    P194

  • Reported: UPOS 1.16b2 — Wed, 23 Mar 2022 03:42 GMT
  • Disposition: Resolved — UPOS 1.16.1
  • Disposition Summary:

    Repaired "method use" descriptions for UPOS1161-7

    See attached spreadsheet for extent of modifications.

    Some "method use" descriptions needed clarification and repair of dashed-terminology that was comma-delimited.

  • Updated: Wed, 13 Jul 2022 14:18 GMT
  • Attachments: