Summary:
StV-6: There is a problem (MODAF's fault) with the description for StV-6. It is supposed to be a mapping between capabilities and doctrinal tasks (StandardOperationalActivity). UPDM should reflect the true intent of StV-6. OperationalActivities which are not StandardOperationalActivities are not allowed in StV-6.
Diagram StV
Document Issue UPDM (OMG Beta) Jan 2009Source Ian BaileyModel Futuresian@modelfutures.com
Resolution Remove OperationalActivity from the StV-6 product diagram and change the text for StV-6 to remove all references to OperationalActivities.
-
Reported: UPDM 1.0b1 — Tue, 17 Mar 2009 04:00 GMT
-
Disposition: Resolved — UPDM 1.0
-
Disposition Summary:
Remove OperationalActivity from the StV-6 product diagram and change the text for StV-6 to remove all references to OperationalActivities.
-