                            Key: UPDM-672
 - 
                            Legacy Issue Number: 13644
 - 
                            Status: closed
 - 
                            Source: PTC ( Phillip Astle)
 - 
                            Summary:
NodePorts are mapped to FlowPorts which limits the elements that can type it. Since InformationElements are extensions of InformationItem they cannot be linked to a FlowPort and as such UPDM invalidate SysML constraints. We do, however, need to connect InformationElements to NodePorts so we cannot just remove it.Same issue with ResourcePort and DataElement.
Diagram OV-2 / SV-2
Document Issue UPDM (OMG Beta) Jan 2009Source Phillip AstleArtisan Software Toolsphillip.astle@artisansoftwaretools.com
Resolution: Change InformationElement to extend Class. Review relationship to EntityAction-Architecture teamPOTENTIAL SOLUTION: Change InformationElement to extend Class? Alternatively, change ports to connect to Entities?Metaclass changed to class
 - 
                            Reported: UPDM 1.0b1 — Fri, 27 Feb 2009 05:00 GMT
 - 
                            Disposition: Resolved — UPDM 1.0
 - 
                            Disposition Summary:
Change InformationElement to extend Class relationship to Entity
 - 