smartant 1.0 FTF Avatar
  1. OMG Issue

SMRTANT — Section: 8.2.4

  • Key: SMRTANT-17
  • Legacy Issue Number: 12346
  • Status: closed  
  • Source: Red Hat ( Robert Kukura)
  • Summary:

    Reference (SmartAnt FTF Issues List): #19 No units have been specified for the Timing and Threshold Synchronization interface attributes whose types are ULong and ULongLong.

  • Reported: smartant 1.0b1 — Thu, 20 Mar 2008 04:00 GMT
  • Disposition: Resolved — smartant 1.0
  • Disposition Summary:

    Both of attributes have no dimension. Supplemental comments will be added in the specification.
    Usually, signals in baseband are represented by complex numbers without unit. Therefore, Threshold attribute has no unit.
    As for Timing attribute, this attribute should be represented in TimeType. It had been resolved before AB approval in Washington DC.

  • Updated: Fri, 6 Mar 2015 23:30 GMT