smartant 1.0 FTF Avatar
  1. OMG Issue

SMRTANT — Section: 8.2.2

  • Key: SMRTANT-16
  • Legacy Issue Number: 12345
  • Status: closed  
  • Source: Red Hat ( Robert Kukura)
  • Summary:

    Reference (SmartAnt FTF Issues List): #17 The CalibrationTable and CalibrationAccuracy attributes of the Calibration interface are of type ComplexSequence. I see no description of what the individual elements of these sequences correspond to. Do they related to individual antenna elements, or maybe times or frequencies? Also, units haven't been specified for these.

  • Reported: smartant 1.0b1 — Thu, 20 Mar 2008 04:00 GMT
  • Disposition: Resolved — smartant 1.0
  • Disposition Summary:

    1. Output of calibration has no units. Therefore both attributes also have no units.
    2. "Each element of CalibrationTable represents a calibration-output which corresponds to each of RF/IF chains." has been added in description of CalibrationTable attribute.
    3. The description of CalibrationAccuracy has been replaced with "The CalibrationAccuracy attribute represents the required variance of calibration-output."

  • Updated: Fri, 6 Mar 2015 23:30 GMT