Key: DDSSEC11-48
-
Status: closed
-
Source: Real-Time Innovations ( Dr. Gerardo Pardo-Castellote, Ph.D.)
-
Summary:
According to the DDS Security specification (9.6 Builtin Logging Plugin), the facility value for the BuiltinLoggingType must be 0x10 (16 in decimal):
octet facility; // Set to 0x10. Indicates sec/auth msgs LoggingLevel severity;
However, according to the Syslog RFC 6.2.1. PRI (https://tools.ietf.org/html/rfc5424):
Facility and Severity values are not normative but often used. They are described in the following tables for purely informational purposes. Facility values MUST be in the range of 0 to 23 inclusive. [...] 10 security/authorization messages [...] 16 local use 0 (local0)
It defines 10 (0x0a) as the value for security/auth messages.
-
Reported: DDS-SECURITY 1.0 — Tue, 7 Feb 2017 00:58 GMT
-
Disposition: Resolved — DDS-SECURITY 1.1
-
Disposition Summary:
Changes in Specification to correct logging facility
Changes in Specification to correct logging facility as per
DDSSEC11-48 -
Updated: Tue, 19 Dec 2017 20:03 GMT
DDSSEC11 — Wrong Facility Value for Logging Plugin
- Key: DDSSEC11-48
- OMG Task Force: DDS Security 1.1 RTF