Key: CORBA24-160
-
Legacy Issue Number: 3561
-
Status: closed
-
Source: Thematix Partners LLC ( Jishnu Mukerji [X] (Inactive))
-
Summary:
In document ptc/00-03-02 on page 13-30 in the last bullet on that page it says: "If a system
exception is raised , it shall be BAD_PARAM with an OMG standard minor code of 1".This cannot be right because the OMG standard minor code of 1 for BAD_PARAM is assigned to "failure
to register, unregister or lookup value factory."I recommend that we change this minor code to a new one that is properly allocated with the
associated text that reads something like: "Service context not understood". I am still wondering
though why BAD_PARAM is the correct exception to raise. Wouldn't BAD_CONTEXT be more appropriate?In any case we have to change the minor code, even if we cannot make up our minds about which
exception. -
Reported: CPP 1.1 — Fri, 14 Apr 2000 04:00 GMT
-
Disposition: Resolved — CORBA 2.4
-
Disposition Summary:
resolved and closed
-
Updated: Fri, 6 Mar 2015 20:58 GMT
CORBA24 — Wrong minor code specified in Chapter 13
- Key: CORBA24-160
- OMG Task Force: CORBA Core 2.4 RTF