    Alarms in XTCE are only available for parameters of type integer or float. In SCOS 2K, alarms
    are defined for any type of parameter. Moreover alarms in S2K can be of several types: soft limit - hard limit- delta check - status consistency (linke to relevant telemetry parameter) - event generation - or application specific. For this reason a attribute or element describing the type of the alarm (proprietary list or constrained value list) would be the best.

  • Reported: XTCE 1.0 — Thu, 1 Dec 2005 05:00 GMT
  • Disposition: Resolved — XTCE 1.1
  • Disposition Summary:

    No Data Available