Key: UML22-218
-
Legacy Issue Number: 9807
-
Status: closed
-
Source: oose Innovative Informatik eG ( Mr. Tim Weilkiens)
-
Summary:
Fig. 8.12 shows delegate connectors that are directly connected with an interface. According to the metamodell that's not possible. A connector end can only be connected with connectable elements.
-
Reported: UML 2.1.1 — Wed, 7 Jun 2006 04:00 GMT
-
Disposition: Resolved — UML 2.2
-
Disposition Summary:
Resolution:
Resolved by the changes specified in 8168.Revised Text:
None.
Disposition: Duplicate of 8168. -
Updated: Fri, 6 Mar 2015 20:58 GMT