Key: SYSPISF_-16
-
Status: closed
-
Source: Airbus Group ( Mr. Yves Bernard)
-
Summary:
For example: Conserved variables should be continuous. Continuous variables must be Real. Constants and variables should have redefinition constraints. Variables should have constraints for when they are on blocks typing connected parts or ports in internal block diagrams. Multiplicities on constants and variables are missing.
-
Reported: SysPISF 1.0b1 — Tue, 19 Sep 2017 18:36 GMT
-
Disposition: Duplicate or Merged — SysPhS 1.0
-
Disposition Summary:
Merge
SYSPISF_-16intoSYSPISF_-5Merge
SYSPISF_-16withSYSPISF_-5 -
Updated: Mon, 2 Apr 2018 18:09 GMT
SYSPISF_ — Missing constraints and multiplicities on SimConstant and SimVariable
- Key: SYSPISF_-16
- OMG Task Force: SysPISF 1.0 FTF 2