Key: SYSPHS12-23
-
Status: open
-
Source: Webel IT Australia ( Dr. Darren Kelly)
-
Summary:
The water temperature from TemperatureIncreaseConstraint and HeatingCalculationConstraint starts at 0 °C (it should probably start at the environment temperature 20 °C).
{increase=energy/(specificHeat*waterVolume)}
{tOut=max(min(100,x),0)} {der(x)=tInc/c1}
HeatingCalculationConstraint needs an additional parameter as integration constant with a realistic initial value set via an additional value property binding in HeatingCalculation.
-
Reported: SysPhS 1.1 — Thu, 25 Feb 2021 22:56 GMT
-
Updated: Wed, 3 Mar 2021 00:46 GMT
-
Attachments:
SYSPHS12 — The water temperature from TemperatureIncreaseConstraint and HeatingCalculationConstraint starts at 0 °C
- Key: SYSPHS12-23
- OMG Task Force: SysPhS 1.2 RTF