Key: SYSPHS12-11
-
Status: open
-
Source: Webel IT Australia ( Dr. Darren Kelly)
-
Summary:
Advise against diagramming style used in examples Figure 68 and Figure 69, which show overlapping Connectors in Internal Block Diagrams
In Figure 68: Internal structure of the humidifier, from a Port named vapourOut.
In Figure 69: Internal structure of the vapor generation plant, from a Port named temperatureOut.
This can give a false impression of shared channel (and implied sum of flow).
In the case of electrical current, the lines drawn that way indeed by convention imply currents meeting a node, whereas in the SysML diagram there is no node at all.
-
Reported: SysPhS 1.1 — Thu, 11 Feb 2021 11:17 GMT
-
Updated: Sat, 27 Feb 2021 10:38 GMT
-
Attachments:
- ElectricCircuit-composite-overlapping-vs-Webel.png 1.23 MB (image/png)
- sysphs-1-1-snap-figure48-issue-overlapping-Connector.png 180 kB (image/png)
- sysphs-1-1-snap-figure68-figure69-DK-SYSML-156-prefer-no-overlap.png 196 kB (image/png)
SYSPHS12 — Overlapping Connectors in iBDs can give false impression of shared channel (and implied sum of flow)
- Key: SYSPHS12-11
- OMG Task Force: SysPhS 1.2 RTF