Key: SYSMLR-285
-
Status: closed
-
Source: Airbus Group ( Mr. Yves Bernard)
-
Summary:
In the current version of SysML.xmi, all the stereotype properties referring to the element to which the stereotype is applied (the so-called "base_xxx" ones) have [0..1] multiplicities, except for the following stereotypes: FlowSpecification (deprecated), FlowPort (deprecated) and TriggerOnNestedPort.
Basically, these multiplicities shall be [1..1] except for stereotypes that may be applied to more than one metaclass. That is for SysML: TestCase, Rate, Probability and ControlOperator
-
Reported: SysML 1.4 — Wed, 10 Aug 2016 11:01 GMT
-
Disposition: Deferred — SysML 1.5
-
Disposition Summary:
This Issue was not resolved in this Task Force and was automatically deferred to the next Task Force
-
Updated: Tue, 3 Jan 2017 13:36 GMT
SYSMLR — Incorrect multiplicity for base_xxx properties of most SysML Stereotypes
- Key: SYSMLR-285
- OMG Task Force: SysML 1.5 RTF