SysML 1.5 RTF Avatar
  1. OMG Issue

SYSMLR — Incorrect multiplicity for base_xxx properties of most SysML Stereotypes

  • Key: SYSMLR-285
  • Status: closed  
  • Source: Airbus Group ( Mr. Yves Bernard)
  • Summary:

    In the current version of SysML.xmi, all the stereotype properties referring to the element to which the stereotype is applied (the so-called "base_xxx" ones) have [0..1] multiplicities, except for the following stereotypes: FlowSpecification (deprecated), FlowPort (deprecated) and TriggerOnNestedPort.

    Basically, these multiplicities shall be [1..1] except for stereotypes that may be applied to more than one metaclass. That is for SysML: TestCase, Rate, Probability and ControlOperator

  • Reported: SysML 1.4 — Wed, 10 Aug 2016 11:01 GMT
  • Disposition: Deferred — SysML 1.5
  • Disposition Summary:

    This Issue was not resolved in this Task Force and was automatically deferred to the next Task Force

  • Updated: Tue, 3 Jan 2017 13:36 GMT