SysML 1.5 RTF Avatar
  1. OMG Issue

SYSMLR — ParticipantProperty multiplicity

  • Key: SYSMLR-248
  • Status: closed  
  • Source: Dassault Systemes ( Mr. Nerijus Jankevicius)
  • Summary:

    There is a constraint in 8.3.2.12 ParticipantProperty

    [6] The property referred to by end must have a multiplicity of 1.

    What is "property referred to by end??? And why it's multiplicity must be [1]?
    Why it is not set in a profile or metamodel? Why constraint is needed?

    Also, in model example in Figure 8.13 - Internal Block Diagram for WheelHubAssembly

    There is connector typed by AssociationBlock and both ends have multiplicities more than 1.

  • Reported: SysML 1.4 — Mon, 20 Jun 2016 21:06 GMT
  • Disposition: Resolved — SysML 1.5
  • Disposition Summary:

    Apply revision from previously adopted resolution

    Apply revision from http://issues.omg.org/browse/SYSML12-19, as reported in http://doc.omg.org/ptc/09-08-13.pdf (PDF page 75, or search on 13666).

  • Updated: Thu, 6 Apr 2017 13:49 GMT
  • Attachments: