SysML 1.5 RTF Avatar
  1. OMG Issue

SYSMLR — Diagram show inconsistent data

  • Key: SYSMLR-120
  • Legacy Issue Number: 18503
  • Status: closed  
  • Source: PTC ( Phillip Astle)
  • Summary:

    Diagrams C.35, C.36 and C.37 show inconsistent allocation between the displayed items, yet the text would seem to imply that they're supposed to show the same relationships.

    In C.35, the allocation is from an ObjectNode symbol called "DriveCurrent" (which I believe equates to an ObjectFlow - name unknown) to an ItemFlow called "i1".

    In C.36, the allocation is from an ObjectNode called "DriveCurrent" to a Connector (name unknown).

    In C.37, the allocation is from an ObjectFlow called "o6" to a Connector called "epc-emg.1".

    There are a number of issues:

    1. ObjectNode is an abstract specialization of ActivityNode and as such you can't have any instances of them in a model. Any reference to an ObjectNode should be removed.

    2. The allocation should consistently be from ObjectFlow "o6" to either ItemFlow "i1" or Connector "epc-emg.1".

    3. In order to make it clear that the same items are being related, the names of the ObjectFlow and the Connector/ItemFlow should be shown on all diagrams. Currently the ObjectFlow and the Connector names are not shown.

  • Reported: SysML 1.3 — Tue, 26 Feb 2013 05:00 GMT
  • Disposition: Deferred — SysML 1.5
  • Disposition Summary:

    Defer

    Postponed to the next RTF

  • Updated: Thu, 6 Apr 2017 13:49 GMT