  1. OMG Issue

SYSML16 — Binding connectors in internal block diagrams must always show the keyword

  • Key: SYSML16-395
  • Status: closed  
  • Source: oose Innovative Informatik eG ( Mr. Tim Weilkiens)
  • Summary:

    According to table 8.4 it is allowed to show a binding connector without keyword <<equal>>. In that case it is identical with the normal Connector and makes the diagram ambiguous. The keyword should be mandatory.

  • Reported: SysML 1.5 — Thu, 18 Jan 2018 09:47 GMT
  • Disposition: Resolved — SysML 1.6
  • Disposition Summary:

    Make keyword notation for binding connectors in internal block diagrams mandatory

    Binding connectors without a keyword in internal block diagrams could not be distinguished from normal Connectors. The keyword must be mandatory to avoid ambiguity.