Key: SYSML14-12
-
Legacy Issue Number: 17257
-
Status: closed
-
Source: Dassault Systemes ( Mr. Nerijus Jankevicius)
-
Summary:
reference properties "sp" in all subtypes must redefine "sp" from block P.
{redefines}
also, p1, p2, p3 in Plug Design 1 - are they redefining or not? if yes, must beused, if not, how <<proxy>> appears there?
-
Reported: SysML 1.3 — Tue, 20 Mar 2012 04:00 GMT
-
Disposition: Resolved — SysML 1.4
-
Disposition Summary:
Add the suggested redefinition notations
-
Updated: Fri, 6 Mar 2015 20:58 GMT