Key: SDO11-29
-
Legacy Issue Number: 6328
-
Status: open
-
Source: Fraunhofer FOKUS ( Raju N. Vaidya)
-
Summary:
The specification does not specify how a configuration can be modified.
No operation to modify existing configuration sets is defined in the configuration interface. A method should be introduced for this purpose or how it can be done should be clearly defined (eg. Existing set is modified if the configuration is stored in the same name.). Possible options: - Add operation to modify stored configurations - Explain that to modify, the configuration set must first be removed and again be stored with the same name but with new values. - Explain that if confirationset is stored with the name that already exists then that configurationSet is modified. This method has disadvantage since same id can be given without knowledge that it already exists. For this, before storing the configurationSet it may need to check if the given id does not exist, which may be operation overhead.
-
Reported: SDO 1.0 — Wed, 15 Oct 2003 04:00 GMT
-
Updated: Wed, 11 Mar 2015 11:15 GMT
SDO11 — The specification does not specify how a configuration can be modified
- Key: SDO11-29
- OMG Task Force: Super Distributed Objects 1.1 RTF