Key: RAAML-1
-
Status: closed
-
Source: Dassault Systemes ( Mr. Tomas Juknevicius)
-
Summary:
At the moment it is not possible to connect the transfer in to a gate with a connector properly-typed-by-association, because
TransferIn type is FTATree, not the Event
and gate source association currently connects Gate and Event;To address this, Gate.sourceEvent type needs to be widened to FTAElement (which allows both Event and FTATree)
-
Reported: RAAML 1.0b1 — Wed, 17 Feb 2021 13:55 GMT
-
Disposition: Resolved — RAAML 1.0
-
Disposition Summary:
Gate.sourceEvent type needs to be widened to FTAElement
At the moment it is not possible to connect the transfer in to a gate with a connector properly-typed-by-association, because
TransferIn type is FTATree, not the Event
and gate source association currently connects Gate and Event; -
Updated: Thu, 31 Mar 2022 19:32 GMT
-
Attachments:
- 10.8.png 42 kB (image/png)
- 9.42.png 5 kB (image/png)
- 9.44.png 5 kB (image/png)
- 9.53.png 5 kB (image/png)
- 9.59.png 7 kB (image/png)
- RAAMLBug.png 42 kB (image/png)
- RAAMLBug2.png 35 kB (image/png)
RAAML — Gate.sourceEvent type needs to be widened to FTAElement
- Key: RAAML-1
- OMG Task Force: Risk Analysis and Assessment Modeling Language (RAAML) 1.0 FTF