MARTE 1.2 RTF Avatar
  1. OMG Issue

MARTE12_ — MARTE Clocks

  • Key: MARTE12_-8
  • Legacy Issue Number: 16609
  • Status: closed  
  • Source: Commissariat a l Energie Atomique-CEA ( Dr. Sebastien Gerard)
  • Summary:

    In the time chapter, I was reading the following sentence in clause 9.3.1.1: “When the property "on" is not specified, it should be understood as being by default, a dense chronometric clock with no flaws that represent the physical time.”

    However, the lower bound of the multiplicity of the on role from TimedElement to Clock is one, meaning that one value at least has to be specified. May the aforementioned sentence should be repharsed, isn’t?

  • Reported: MARTE 1.0 — Sat, 15 Oct 2011 04:00 GMT
  • Disposition: Resolved — MARTE 1.2
  • Disposition Summary:

    Update the paragraph in question according to the proposed resolution

    The goal here was to ease the creation of the model while always keeping an explicit clock serialized in the model when the designer does not specify it explicitly. We have to specify in the text that a link to the idealClk clock must be set by the modeling tool when the designer does not explicit it (i.e. as a default clock).

  • Updated: Wed, 19 Dec 2018 16:37 GMT