Key: DDS11-120
-
Legacy Issue Number: 8578
-
Status: closed
-
Source: Real-Time Innovations ( Dr. Gerardo Pardo-Castellote, Ph.D.)
-
Summary:
The table in 2.1.5 says that built-in DataReaders should have TRANSIENT durability. However, the description of that durability states that support for it is optional.
Proposed Resolution:
The specification should be changed to state that built-in readers should have TRANSIENT_LOCAL durability.
Proposed Revised Text:
Change TRANSIENT to TRANSIENT_LOCAL in the DURABILITY row of the table on page 2-129.
-
Reported: DDS 1.0 — Mon, 14 Mar 2005 05:00 GMT
-
Disposition: Resolved — DDS 1.1
-
Disposition Summary:
No Data Available
-
Updated: Fri, 6 Mar 2015 20:58 GMT
DDS11 — R#179) Built-in DataReaders should have TRANSIENT_LOCAL durability
- Key: DDS11-120
- OMG Task Force: Data Distribution Service RTF