In section 2.1.3.4 it is unclear whether the service is expected to
check compatibilities between DEADLINE and TIME_BASED_FILTER
policies. For example, a DataWriter offering a DEADLINE period smaller
than a DataReaders TIME_BASED_FILTER is bound to lead to problems with
reliable transmission.Another example is a DataReader which has a DEADLINE period smaller
than the TIME_BASED_FILTER period.**PROPOSAL**
State that DataReader which has a DEADLINE period smaller than the
TIME_BASED_FILTER period results on INCONSISTENT_POLICY. -
Reported: DDS 1.0b1 — Tue, 23 Dec 2003 05:00 GMT
-
Disposition: Resolved — DDS 1.0
-
Disposition Summary:
see below
-