Key: CORBA25-16
-
Legacy Issue Number: 4217
-
Status: closed
-
Source: Anonymous
-
Summary:
The mode attribute can only be set to OP_ONEWAY if the result is TC_void and all
elements of params have a mode of PARAM_IN.which might be taken to mean that the mode attribute must be set to
OP_ONEWAY if the signature is as described. A better wording might beThe mode attribute can be set to OP_ONEWAY only if the result is TC_void and all
elements of params have a mode of PARAM_IN.This was brought to my attention by an email question I received today, from
someone who thought he understood CORBA oneway semantics until he
read that sentence - then he became confused. -
Reported: CORBA 2.4.2 — Fri, 2 Mar 2001 05:00 GMT
-
Disposition: Resolved — CORBA 2.5
-
Disposition Summary:
make it so
-
Updated: Fri, 6 Mar 2015 20:58 GMT
CORBA25 — misleading wording in 10.5.22.2 Write Interface
- Key: CORBA25-16
- OMG Task Force: Core December 2000 RTF