ALMAS 1.0 FTF Avatar
  1. OMG Issue

ALMAS — Include parameter AlertReceiverSet: StringSet (as with RaiseAlertFromOverrides)

  • Key: ALMAS-23
  • Legacy Issue Number: 13015
  • Status: closed  
  • Source: THALES ( Bert Van Der Meer)
  • Summary:

    By means of RaiseAlertFromData an alert can be raised that is not present in the ALMAS template database. However, receivers (ReceiverKind, see Section 6.2) can only be associated with templates. How can receivers now be defined? Solution: Include parameter AlertReceiverSet: StringSet (as with RaiseAlertFromOverrides)?

  • Reported: ALMAS 1.0b1 — Mon, 9 Feb 2009 05:00 GMT
  • Disposition: Resolved — ALMAS 1.0
  • Disposition Summary:

    To reduce the complexity of this the approach taken is to change the AlertData parameter type to be an AlertTemplate parameter - this is not read or initialised from the XML, so the TemplateID field is invalid, but it reduces the complexity of the interface significantly.