Multiple DataReaders per topic on secured Participant
-
Key: DDSSEC_-190
-
Status: open Implementation work Blocked
-
Source: ZettaScale Technology ( Mr. Julien Enoch)
-
Summary:
Looking at the datareader_crypto parameter description of the preprocess_secure_submsg operation:
"If secure_submessage_category is DATAWRITER_SUBMESSAGE, the datareader_crypto shall be the DatareaderCryptoHandle returned by a previous call to register_local_datareader for the DataReader that is the destination of the RTPS Submessage."
It seems that only a single DatareaderCryptoHandle can be returned. This implies that a secure DATAWRITER_SUBMESSAGE should be at destination of a single DataReader.
How to deal with several DataReaders in a Participant matching the same DataWriter ? Most of the time, the submessage destination is ENTITY_UNKOWN. As a consequence a clarification is required.
-
Reported: DDS-SECURITY 1.0 — Tue, 29 Aug 2017 15:45 GMT
-
Updated: Wed, 30 Aug 2017 15:16 GMT