Key: XTCE12-163
-
Legacy Issue Number: 9063
-
Status: closed
-
Source: Anonymous
-
Summary:
ource: M. Pecchioli mauro.pecchioli@esa.i
Description : It seems that logarithmic calibrations are not supported by thestandard. I think
this should be added.-----Added after meeting with clarification by MP of 18Apr05:
What we support in S2K is the following:
In the case of parameters associated to a logarithmmic calibration, the engineering
value ‘Y’ corresponding to the raw value ‘X’ of a parameter is calculated usingthe
following formula:
Y = 1 / [A0 + A1*ln(X) + A2*ln2(X) + A3*ln3(X) + A4*ln4(X)]
Resolution: Question: Would a polynomial approximation be close enough? Whatforms of
logarithmic calibration are required: natural, base 10 other. What direction of
conversions are required?Discussion: what is ln2 (a base 2 log or the second natural log?)
-
Reported: XTCE 1.0 — Wed, 12 Oct 2005 04:00 GMT
-
Disposition: Duplicate or Merged — XTCE 1.2
-
Disposition Summary:
Merge with Calibrator Issue
XTCE12-152contains a better description of the missing calibration capabilities. -
Updated: Tue, 10 Jul 2018 14:22 GMT
XTCE12 — MP-004 Logarithmic calibrations
- Key: XTCE12-163
- OMG Task Force: XML Telemetric & Command Exchange Format 1.2 (XTCE) RTF