Key: UPOS1151-31
-
Status: open
-
Source: Free Software Developer ( Martin Conrad)
-
Summary:
For the box "Card in PointCard R/W", the labeling of the DataEvent arrow (DataEventEnabled==true & error) is wrong. It must be changed to "DataEventEnabled==true & no error".
For Writing and Printing Mode, the contents of DataEventEnabled is not relevant because DataEventEnabled controls the input model. It does not affect event handling that belongs to the output model. Therefore, the text "DataEventEnabled==true & " should be removed from the OutputCompleteEvent and (output) ErrorEvent arrow. In addition, "error" should be replaced by "no error" in case of the labeling of the OutputCompleteEvent arrow. -
Reported: UPOS 1.15 — Sun, 26 Mar 2023 19:56 GMT
-
Updated: Tue, 9 Jul 2024 00:52 GMT
-
Attachments:
- 1151-30_PointCard RW State Diagram.pptx 350 kB (application/vnd.openxmlformats-officedocument.presentationml.presentation)
- 1151-31_PointCardReaderWriter_NoBar.docx 971 kB (application/vnd.openxmlformats-officedocument.wordprocessingml.document)
- 1151-31_PointCardReaderWriter_with Bar.docx 1.08 MB (application/vnd.openxmlformats-officedocument.wordprocessingml.document)
UPOS1151 — Several Errors in Point Card Reader State Diagram
- Key: UPOS1151-31
- OMG Task Force: UnifiedPOS 1.15.1 RTF