UPOS 1.15.1 RTF Avatar
  1. OMG Issue

UPOS1151 — ToneIndicator: Mismatch in access constraints between Summary and Property description sections

  • Key: UPOS1151-1
  • Status: open  
  • Source: Diebold Nixdorf Global Solutions B.V. ( Mr. Denis Kuniss)
  • Summary:

    During our ToneIndicator implementation we encountered that for several properties the access constraints in the Summary section are different from those in the sections describing the particular property. The Summary section states the properties are accessible only after enable. However, the particular property section defines the property is accessible just after open.

    The following properties are affected (all non-capabilities):

    • AsyncMode
    • InterToneWait
    • MelodyType
    • MelodyVolume
    • Tone1Duration
    • Tone1Pitch
    • Tone1Volume
    • Tone2Duration
    • Tone2Pitch
    • Tone2Volume

    We propose to resolve this differently for the particular properties:

    For AsyncMode the Summary section must be corrected to allow access just after open. This would be equal to to the constraint specified for POSPrinter or FiscalPrinter which are also output devcies.

    For all other properties the Summary section should be considered as being right and the property description section should be changed to allow the access only after enabling.

    Attached are the Summary with the constraint in question marked, and 2 examples of the property descriptions for AsyncMode and InterToneWait.

  • Reported: UPOS 1.15 — Fri, 18 Sep 2020 11:34 GMT
  • Updated: Thu, 11 Jan 2024 14:47 GMT