Key: SYSML2_-456
-
Status: closed
-
Source: Dassault Systemes ( Mr. Tomas Juknevicius)
-
Summary:
There is an inconsistency between Table 14. Actions - Representative Notation (specifically the 'Parameters Compartment' element) and the Graphical BNF.
In the table, the 'return' keyword is displayed before the name of the 'param4' feature. However, the 'return' keyword is specified under the 'ReturnParameterMember' element, which is not included in the 'parameters-compartment-element' specification. As a result, based on the BNF, the 'return' keyword should not appear in the parameters compartment. -
Reported: SysML 2.0b2 — Mon, 23 Dec 2024 09:54 GMT
-
Disposition: Deferred — SysML 2.0b4
-
Disposition Summary:
Defer to RTF
This issue was submitted after the end of the comment period, and the FTF has decided to defer its consideration to a future RTF.
-