Key: SYSML21-588
-
Status: open
-
Source: Aerospace Corporation ( Mr. Ryan Noguchi)
-
Summary:
For import relationships, the visibility indicator (e.g., private, public, etc.) is required in the textual notation but is optional in the graphical notation.It should be made required in the graphical BNF (8.2.3.5) to conform with the textual notation.
-
Reported: SysML 2.0b2 — Mon, 23 Feb 2026 18:44 GMT
-
Updated: Tue, 24 Feb 2026 09:59 GMT
SYSML21 — Inconsistencies in visibility indicator on import relationships between textual and graphical notations
- Key: SYSML21-588
- OMG Task Force: Systems Modeling Language (SysML) 2.1 RTF