Key: SYSML2-2
-
Status: closed
-
Source: oose Innovative Informatik eG ( Mr. Tim Weilkiens)
-
Summary:
The subsetting of the ItemFlowEnd should be a ReferenceSubsetting instead of a Subsetting.
The value of the isEnd property of the ItemFlowEnd is false, but should be true.
It is misleading that the names of the mapping classes for the ItemFlowEnd mapping contain the string ItemFlow. It should be ItemFlowEnd.
-
Reported: SysML 2.0a1 — Sat, 15 Apr 2023 09:08 GMT
-
Disposition: Resolved — SysML 2.0b2
-
Disposition Summary:
ItemFlowEnds of ObjectFlow transformation: isEnd=true, ReferenceSubsetting, and rename mapping classes
The ItemFlowEnd::isEnd property must be set to "true" and the owned Subsetting must be a ReferenceSubsetting.
The naming of the mapping classes for the ItemFlowEnd is a bit misleading. The name should contain the string "ItemFlowEnd" instead of just "ItemFlow".
-
Updated: Tue, 1 Jul 2025 14:47 GMT
SYSML2 — ItemFlowEnds of ObjectFlow transformation target are not defined correctly
- Key: SYSML2-2
- OMG Task Force: Systems Modeling Language (SysML) 2.0 FTF