SysML 1.3 RTF Avatar
  1. OMG Issue

SYSML13 — partWithPort change from UML needs to be clearly stated

  • Key: SYSML13-16
  • Legacy Issue Number: 16008
  • Status: closed  
  • Source: PTC ( Mr. Simon Moore)
  • Summary:

    From discussion within the MIWG (raised at Sandy's request).

    In UML 2.3 partWithPort is clearly only valid for a connector connected to a Port. SysML appears to expect this to be used when a connector is connected to any nested Property. This breaks the UML constraint and needs to be stated clearly in the SysML specification.

  • Reported: SysML 1.2 — Fri, 4 Feb 2011 05:00 GMT
  • Disposition: Resolved — SysML 1.3
  • Disposition Summary:

    This issue overlaps with issue 16045, which was raised in response to the
    same MIWG discussions. SysML NestedConnectorEnd does apply to any nested
    property, but the resolution for 16045 removes the specific SysML constraint that
    conflicts with UML constraints for partWithPort. SysML nested connector ends
    and partWithPort, under all its UML constraints, can both be present and be
    given values for nested connector ends that satisfy both their conditions.
    Disposition: See issue 16045 for disposition

  • Updated: Fri, 6 Mar 2015 20:58 GMT