Summary:
It is mandatory that at the end of each round is an Inter-Round-Gap (IRG) of at
least one slot. This gap leaves a slave enough time to process an MSA round.
Thus there is no need for setting constraints to the order of the rounds. In Section
2.3.6 the following sentence should be removed then:
“Between any two MP rounds there must be an interval of sufficient
duration to execute one phase of an MS round, as depicted in Figure 2-5.” -
Reported: SMART 1.0b1 — Tue, 27 Aug 2002 04:00 GMT
-
Disposition: Resolved — SMART 1.0
-
Disposition Summary:
Accept changes as proposed.
-