Key: PLM2-18
-
Legacy Issue Number: 11215
-
Status: closed
-
Source: PROSTEP AG ( Guido Adolphi)
-
Summary:
PLM Services 2.0, mantis/07-03-01 Update, Chapter 9.7.38 and Figure 9.54 Cause: Location step instance effective_element_step is defined incompletely. New Specification Text: Location step instance effective_element_step in figure 9.54 needs attribute role_declaring_type_name set to Effectivity_assignment and attribute role_name set to effective_element.
-
Reported: PLM 1.0.1 — Fri, 27 Jul 2007 04:00 GMT
-
Disposition: Resolved — PLM 2.0b2
-
Disposition Summary:
Location step instance effective_element_step in figure 9.54 needs attribute role_declaring_type_name set to Effectivity_assignment and attribute role_name set to effective_element.
-
Updated: Fri, 6 Mar 2015 20:58 GMT