CORBA 3.5b1 RTF Avatar
  1. OMG Issue

CORBA35 — Reusing PASSTHRU

  • Key: CORBA35-310
  • Legacy Issue Number: 2866
  • Status: open  
  • Source: Anonymous
  • Summary:

    Summary: Description:
    Reusing PASSTHRU connections by the firewall should be
    expressly disallowed by the specification. With the current wording of the
    specification, a vendor may attempt to reuse PASSTHRU connections. While
    this will work in some cases, it is not interoperable because there are
    cases when reusing PASSTHRU connections will not work. For example,
    connection reuse when SSL is in use will not work because all of the
    information that distinguishes data streams is contained within the
    encrypted portion of SSL packets. If two SSL connections try to share a
    single connection, there will be an SSL protocol failure because the server
    will not be able to separate the data streams before it processes the SSL
    packet.

  • Reported: CORBA 2.3.1 — Tue, 24 Aug 1999 04:00 GMT
  • Updated: Wed, 26 Jun 2024 00:56 GMT