Key: CORBA34-326
-
Legacy Issue Number: 2638
-
Status: closed
-
Source: Anonymous
-
Summary:
Summary: In ptc/98-10-11 5.8.1 it says "If a client has not set up any mechanism for
traditional-style callbacks using a listening socket, then the port entry
in its IOR must be set to the outgoing connection"s local port (as
retrieved using the getsockname() sockets API call)". At IOR creation time
there may be no connection, or there may be many, so the mandated local
port may be non-existent or ambiguous.This topic was discussed on the firewall-rtf list during Feb-Mar 1999 but
was not raised as an issue. -
Reported: CORBA 2.3 — Thu, 6 May 1999 04:00 GMT
-
Disposition: Deferred — CORBA 3.4
-
Disposition Summary:
Deferred
This proposal was generated automatically by request of the Task Force Chair Adam Mitz.
-
Updated: Wed, 1 Feb 2023 21:59 GMT