                            Key: CORBA3-106
- 
                            Legacy Issue Number: 5093
- 
                            Status: closed
- 
                            Source: Zuehlke Engineering ( Frank Pilhofer)
- 
                            Summary:On page 69-521 (ptc/01-11-03), the connectevent 
 element of an Assembly Descriptor is defined as<!ELEMENT connectevent (consumesport, 
 (emitsport |
 publishesport))>This does not allow for emits and publishes 
 ports to be connected to existing consumer
 interfaces that are registered in the naming
 or trading service. I suggest to change that
 element in the spirit of connectinterface to<!ELEMENT connectevent (emitsport | 
 publishesport) ,
 (consumesport |
 existinginterface)>
- 
                            Reported: CORBA 2.6 — Tue, 26 Mar 2002 05:00 GMT
- 
                            Disposition: Resolved — CORBA 3.0.2
- 
                            Disposition Summary:see above 
- 
                            Updated: Fri, 6 Mar 2015 20:58 GMT