-
Key: CORBA3-106
-
Legacy Issue Number: 5093
-
Status: closed
-
Source: Zuehlke Engineering ( Frank Pilhofer)
-
Summary:
On page 69-521 (ptc/01-11-03), the connectevent
element of an Assembly Descriptor is defined as<!ELEMENT connectevent (consumesport,
(emitsport |
publishesport))>This does not allow for emits and publishes
ports to be connected to existing consumer
interfaces that are registered in the naming
or trading service. I suggest to change that
element in the spirit of connectinterface to<!ELEMENT connectevent (emitsport |
publishesport) ,
(consumesport |
existinginterface)> -
Reported: CORBA 2.6 — Tue, 26 Mar 2002 05:00 GMT
-
Disposition: Resolved — CORBA 3.0.2
-
Disposition Summary:
see above
-
Updated: Fri, 6 Mar 2015 20:58 GMT